| Defect | Description |
| 18942 | The "Use Measured Product Property" calibration option in DC-SIM not functioning properly in Monitoring mode |
| 17434 | Synthesis error causes negative yields |
| 18542 | Target of "R1 Nitrogen, Overall Conversion" for 2-Stage HCR improperly adjusts R2 bed inlet temperatures |
| 18564 | Petro-SIM hangs when used with OPC Expert |
| 18747 | Biodiesel Water handling bug causes non-Biodiesel case to have mass imbalance due to presence of C6+ material in gas feed |
| 18761 | Feeder not reliably copying the bulk properties |
| 18765 | Cloning predict reactor crashes due to historian link problem |
| 18780 | Logical op connections don't recall properly if the moniker is not strongly-typed |
| 18916 | Pour point synthesis crashes with Levenberg Marquardt scheme |
| 19153 | Memory corruption related crash in air cooler case |
| 19167 | Incorrect valve sizing calculations for flashing liquids |
| 19252 | RDHTR: Reactor fails to solve with warning about negative LV for C1 |
| 14534 | Problem sending model inputs to Predict Input worksheet |
| 14998 | AM-SIM column results not transferring correctly |
| 18405 | Emissions variables not available to the MVN |
| 18406 | CO:CO2 ratio not being reported correctly in regenerator 2 |
| 18457 | Assay allow revisions but do not show updates |
| 18505 | Mole Frac in meter coming into synthesis as mole percentage |
| 18527 | LPU using the wrong flows for Swing Cut properties calculations |
| 18528 | LPU not using the specified pair rule for a swing cut property (light over average) |
| 18545 | Model reports negative Corrected Conversion Per Pass when external liquid feed to R3 contains significant amount of converted material |
| 18553 | LPU loosing yield reference stream when not checked in LPU |
| 18563 | [Swing Cut Utility]: Utility not reporting any result on the performance tab |
| 18566 | [Quick Plot]: Show inputs shows Cloud Point values in DegC regardless of the current case Units |
| 18578 | HXM and DRU not tracking changes to meter typical errors |
| 18592 | HX-Monitor is counting the cleaning cost and contribution from the same exchanger multiple times |
| 18599 | Preferences: Some options not applied directly when opening a case |
| 18651 | Synthesis deblending of very light Minus streams messes up the sulfur content assay |
| 18684 | Named variables in spreadsheets have units issues |
| 18771 | Auto-solve optimizer not solving when un-ignored |
| 18781 | Detailed heat loss model does not work in dynamics |
| 18832 | Spreadsheets: Changing the number of columns (or rows) changes the flowsheet tag of the named variables on the spreadsheet |
| 18834 | Spreadsheet: It does not send <empty> to reformer |
| 18850 | Cause and effect matrix reset not working properly |
| 18872 | Moving selected items with the mouse does not move all the objects |
| 18886 | Actuator Commands in Process Data Table |
| 18891 | Shell and Tube Side Mass Flow not available for reports |
| 18892 | Composite Curves Utility not refreshing network data automatically |
| 18903 | Meter: Don’t send a value to a spreadsheet cell that is an import |
| 18904 | Spreadsheet: Deleting an imported value coming from another spreasheet converts the formula into a string |
| 18943 | Explorer not waiting for case to re-solve after HXM data rec pushes spreadsheet cells to re-execute |
| 18944 | Coker Furnace Sample: Sample case not properly configured, consistency error due to extra Data Rec |
| 18957 | Smart scale the Y Axis not properly updating the axis scale for sulfur content |
| 18964 | Embedded, invalid, hidden tag names are getting saved to DB causing issues with some data queries |
| 18977 | SCN Analysis Component Basis wrong |
| 18993 | Ignoring any unit operation, opens a composition input page |
| 19002 | Negative Temp Difference for air cooler during startup |
| 19011 | Problem storing LP utility to database – need to clean up regression setup store to database |
| 19029 | Fired heater view slows integrator down on some pages |
| 19047 | KPI utility not using correct standard conditions for unit conversions |
| 19098 | LPU: Exporting to knowledge base is not working properly |
| 19099 | Calculated values for Vacuum Residue (update contiguous) cut are all empty |
| 19136 | Monitoring cases storing out massive amounts of unnecessary uservariable data |
| 19150 | Wrong liquid density calculation when sizing the valve |
| 19253 | RDHTR: Negative CO in effluent / vent gas |