| Defect | Description |
| 19198 | kbclib synthesis overwrites variables by writing past the end of arrays causing crashes |
| 18942 | The "Use Measured Product Property" calibration option in DC-SIM not functioning properly in Monitoring mode |
| 19284 | FCC-SIM: Thermal cracking check in Riser generate issues for Bed Cracker |
| 19268 | Editting a base delta solver disconnects any spreadsheet connections |
| 19259 | Synthesis generates bogus Viscosity value even though there is no Viscosity input |
| 19252 | RDHTR: Reactor fails to solve with warning about negative LV for C1 |
| 19221 | Surge Controller not calculating an output on MW curves |
| 19217 | HXX produces a different effluent curve between true calibration and back-predict |
| 19216 | HXX succeeds in true calibration but failed in back-predict |
| 19120 | Issues copying with Labels into Excel |
| 18916 | Pour point synthesis crashes with Levenberg Marquardt scheme |
| 18851 | Air Cooler crashes upon store after changing from weighted to basic design |
| 18575 | Databook: Properties send to Databook from Assay Adjuster change when changing the list of adjusted variables |
| 19305 | Indene is absent in C9A sum in the internal model feed |
| 19243 | Excel Add-in Help pointing to a non-existing web page |
| 19156 | Base Delta Table should allow base yields of < 0 and > 1 |
| 19133 | Editting a base delta solver can erase the values from its tables |
| 19099 | Calculated values for Vacuum Residue (update contiguous) cut are all empty |
| 19098 | LPU: Exporting to knowledge base is not working properly |
| 19049 | GetDeltaVarType doesn't support composition variable types |
| 19034 | Basecase not recognise in KBC Explorer Application when the name has " |
| 18915 | HXX: true error message suppressed due to too many occurrences of Note #111 and Note #141 |
| 18892 | Composite Curves Utility not refreshing network data automatically |
| 18733 | Variable sets not changing in LPU when a column is selected for the swingcuts (no swingcut inserted) |
| 18541 | LPU regression plots not calculating correctly |
| 18405 | Emissions variables not available to the MVN |
| 15468 | HCR-SIM Convergence Target is not met |
| 19397 | Property Table collecting incorrect values |
| 19338 | Slow deleting process data tables due to undo information |
| 19254 | Case takes a long time due to multiflash model building |
| 19253 | RDHTR: Negative CO in effluent / vent gas |
| 19219 | Inconsistency in calibration due to spreadsheets in the simulation case |
| 19166 | Issue connecting spreadsheet to a valve |
| 19150 | Wrong liquid density calculation when sizing the valve |
| 19136 | Monitoring cases storing out massive amounts of unnecessary uservariable data |
| 19064 | Pressure flow k sizing calculation not using reference flow |
| 19047 | KPI utility not using correct standard conditions for unit conversions |
| 19011 | Problem storing LP utility to database - need to clean up regression setup store to database |
| 19002 | Negative Temp Difference for air cooler during startup need fixing |
| 18964 | Embedded, invalid, hidden tag names are getting saved to DB causing issues with some data queries |
| 18943 | Explorer not waiting for case to re-solve after HXM data rec pushes spreadsheet cells to re-execute |
| 18904 | Spreadsheet: Deleting an imported value coming from another spreasheet converts the formula into a string |
| 18903 | Meter: Don't send a value to a spreadsheet cell that is an import |
| 18891 | Shell and Tube Side Mass Flow not available for reports |
| 18871 | Copy paste does not restore full PFD positioning |
| 17693 | CDB: FCC_SIM override catalyst percent in mix with 0 if the catalyst number is 0 |