Change List PS
List of improvements included in this service pack
| Defect | Description |
| 20504 | Amines TP flash calculation fails |
| 20648 | Copy paste a coker into a case with another coker crashes |
| 21320 | KBC Explorer has dependency on Telerik version with critical security vulnerabilities |
| 21555 | Data Set Utility slows every action in the case down severely and makes any large case unusable |
| 21489 | Infinite loop in synthesis code |
| 21880 | Load - Meter Tag option from the workbook is not working |
| 21023 | Strip charts and icons stop painting and simulator becomes unresponsive |
| 21700 | LPU: Crash in the recall of the LPU not handling base delta table had 0 deltas |
| 21259 | Environment change problem in a flowsheet |
| 20197 | Paste Objects from file Crash when selecting pasted objects to use default fluid package |
| 20777 | Petro-SIM crashes in weir code when integrator is started |
| 20801 | Large case crashes after changing component list |
| 21289 | Case crashes on close in signal block |
| 20849 | Crash when pasting in copied coker section |
| 21318 | Crash when connecting one stream to a third cutter |
| 21461 | Saving case to DB fails when case study names have unicode characters |
| 21561 | The compressor model does not converge due to head curve conversion issues |
| 21612 | Journal log causes crash when deleting HCR reactor |
| 21869 | Case crashes on close due to due dangling solver notifications |
| 20586 | FCC-SIM Crash - RI override undo |
| 20712 | Distillation column Range Specs: Connecting lower and upper limit to spreadsheet and using formula triggers infinite loop |
| 20624 | Freeze point calculation in Isomerization reactor and Petro-SIM synthesis mismatch |
| 20864 | DHTR Isomerization: Isoparaffins in feed characterization issues by model |
| 20986 | HXX: IDATA overflows MIDATA limit of 33000 reliably |
| 21247 | HXX: Error #85 negative HPS liq rate is thrown due to faulty flash when the species flow into the HPS is zero |
| 21479 | "Send Data On Solve" seems to interfere with XML export |
| 20274 | Synthesis: Does not match distillation data |
| 20808 | Crash solving Hxx-SIM |
| 20894 | "New ULSD Catalyst Deactivation Mechanism" problem with once-through gas mode |
| 21058 | Same streams have different heating values |
| 21418 | Incorrect Results when running certain LPU Assays |
| 21968 | Property table utility calculates a huge solid phase flowrate |
| 21814 | Send Data on Solve option not working for Distop columns included as Secondary Objects in Meters |
| 21884 | Get property Values not working correctly for Coker furnace Calc Fraction |
| 21919 | Valve always leak malfunction overlaps with worn trim functionality |
| 21924 | Selector reverts to empty on recall when correlation moniker is used. |
| 21695 | Running PS from the same machine that hosts its network licenses not working properly |
| 14084 | Viscosity calculation issues when importing crude assays |
| 20818 | "Property package" calculation method for Specific Gravity (Dry) |
| 20838 | Spreadsheet regional formula problem |
| 20593 | LPU using empty as value to calculate Swing cut properties |
| 20634 | XSimOP Difference with Petro-SIM |
| 21153 | Problems heat exchanger TEMA datasheet and verification in a 2 liquid phase stream |
| 18089 | Coker Furnace: Increase the severity of Feed not defined from Warning to Error |
| 18091 | DC-SIM: Calibration fails due to the presence of an unused external quench stream |
| 21486 | DC-SIM fails calibration without appropriate error message |
| 20435 | FCC-SIM prediction convergence failing when Bed Exit O2 is too low even if it is not the combustion target |
| 20307 | Issues with the scaling of the icons |
| 20322 | Pipe Profile page in the Help File should include more details |
| 20389 | Error in the effluent curve plot in a DHTR-SIM Renewables model |
| 20417 | Steam Ejector needs better zero flow handling |
| 20436 | Steam ejector rating mode not predicting flowrates as expected |
| 20568 | Calibration Env > Data Tab > Active Data (view): Every time new data is added in synthesis meter, PS switch to Column subflowsheet meters |
| 20783 | Separator incorrectly complains about weir dimensions |
| 20834 | Event scheduler tree view does not remember selection and always expands everything |
| 20835 | Separator overall heat loss experiences sudden jump |
| 20873 | Transfer function does not work correctly |
| 21001 | Component splitter calibration fails |
| 21048 | Workbook does not allow selection or copy when transposed |
| 21065 | Pump: The option Enable NPSH curves does not work in PS v7.4SP1 |
| 21272 | Linking column stage holdup liquid recycle efficiency to a spreadsheet gets lost upon recall |
| 21279 | Link in Petro-SIM Help File not working - ISOM SIM calibration |
| 21290 | Column widths in base delta op do not sync properly |
| 20877 | H&MB templates - issue with regional number formats |
| 20911 | Unable to delete chart pages from chart manager |
| 21790 | Tray sizing utility - incorrect warning message for DC sealing |
| 20380 | Heat Exchanger: PFD Table mistaking Wall Temperatures at inlet and outlet |
| 20626 | Autosolve Optimiser in subflowsheet causing issues |
| 20652 | Assay stores Build Number as Index instead of Long, causing incorrect values and forcing resynthesis of most assays |
| 20775 | 3 phase separator doesn't solve |
| 20807 | Solver stuck on Hold when clicking parent from Oil Environment |
| 20841 | LP Utility: Calculated variables can be sent as Manipulated variables from Assay Adjuster worksheet page |
| 20883 | Base delta op is not mapping the Viscosity property in the assay adjuster to the stream viscosity properly |
| 21119 | The embedded BD op in the FCC isn't handling the multi-base table |
| 21219 | Unable to modify valve opening in steady state using a spreadsheet |
| 21244 | Launch.exe needs updated digital signature |
| 21329 | Updating Subscription or closing Manage Subscription window removes Feed checkbox |
| 21330 | Locked button does not work if tables are subscribed from the database |
| 21394 | Condenser pressure inconsistency related to a spreadsheet export |
| 21825 | Regression LPU Sub-model calculations not correct for non-SI units |
| 21848 | Model stuck in read-only mode when saved in oil environment and with license failure |
| 19137 | Adapting ISOM-SIM old and new models to a 1 reactor unit |
| 20641 | DHTR Isomerization: Effluent C6-13 paraffins and reactor results mismatch |
| 20655 | HXX diagnostics log only shows freeze point for first distillate product |
| 20660 | DHTR Renewables Co-processing: SG discrepancy between rx diagnostics and PS stream |
| 20896 | DHTR Isom: Effluent paraffin composition does not match reactor results at certain CN |
| 20897 | DHTR Isom: negative n-paraffin fractions in effluent at C19-C24 |
| 21404 | DHTR Isom: Effluent failed synthesis due to negative n-paraffins |
| 20696 | Flowsheet report - broken "include" checkbox for energy streams |
| 21067 | Explorer not showing sub-folders when parent folder contains a case |
| 21070 | Database historian does not recognize DSN connections |
| 21179 | Case doesn't store out all meters with data |
| 21203 | KBC Explorer can't generate fouling report when Clean All case has empty name |
| 21215 | Petro-SIM lets you connect to DB with trailing spaces in name, leading to failed connections from Explorer |
| 21227 | Can't drag-drop some HX variables to multi-case reports |
| 21228 | Drag-drop of some HX variables into multi-case reports fails if they come from ExchPerf sub-object |
| 21238 | Explorer not showing data for some timestamps in a time series report |
| 21278 | Tag units are not being transferred properly when meter historian connection is changed |
| 21399 | Calibration shows missing composition error when meter has only lipids data |
| 21622 | Explorer adds multiple Reports tabs when multi-selecting cases |
| 21143 | Synthesis fails to check for PONA consistency after naphthenes synthesis |
| 21162 | PTC doesn't calculate flow when one of the cuts is not synthesized because its flow is too small |
| 21496 | Stream synthesis/ meter not accepting component |
| 20882 | New Quench Setup Option unable to calculate R2 B1 HXQ when R2 TG rate is positive (calibration) |
| 20926 | CNHTR diolefin/deS (2RX) Cracking Override does not work for R2 |
| 21487 | Average Deactivation Rate needs to be tagged as tuning factors for PTP to populate the list |
| 21443 | LPDataGen runs not completing properly when running large bulk data sets |
| 21671 | Crude assay change to "Not synthesized" upon opening the case and entering Oil Environment |
| 20364 | Not possible to change from Simulation rating mode to Calculate Fouling on a HX |
| 20534 | Heat Exchanger: Checkbox "Weighted LMTD calculation" make HX to hang and not converge |
| 20613 | CHP Fired Process Heater - Radiant losses not calculating |
| 20956 | HX: Geometry Screening and Optimization does not allow to select small OD |
| 21783 | High viscosity liquids make Hx SSR model fail |