Maximus 7.6 - Physics based Multiphase Flow Simulator

Released: July 2025.
Maintained until July 2028
Release Notes
Important note, before you upgrade
Maximus 7.6 requires Sentinel RMS 10.1. You can upgrade to the new version of the Network License Server directly from the Maximus 7.6 install shield, selecting "Network License Server" or download it directly from the KBC Downloads site
What's new in Maximus 7.6
With Maximus 7.6 we continue with the transition of Maximus from a primarily design tool to a tool that can be used across the project lifecycle, from early stages of design to operations management and field-wide production optimization.
List of changes in Maximus 7.6
- New or improved functionalities
- Automatic plotting of IPR curves
- Ability to superimpose a VFP curve onto IPR curve and thus display Nodal Analysis plot for a well
- Ability to utilize VLP curves to model the wellbore performance from Bottom Hole to Wellhead
- Tuning of a complete field to known pressures and flowrates
- New constraints added to Gas Lift Optimization including: Min. & Max. flowrate, Max. Drawdown, Min, FBHP, Min. & Max. WH velocity
- Sensitivity studies can turn GLO on or off
- Added new Model Variable Functions. See Maximus Help System for more details.
- Direct coupling with the Reservoir Simulator 6X from Ridgeway Kite
- Improvements to the UWA Hydrate model
- Updated pipe schedule database
- Allow option to set ambient temperature as a depth for whole system
- Added Gas Sizing equation for chokes
- Auto-save model prior to a simulation
- WGR & GWR added as option to Phase ratios for Black Oil
- Added X-axis variable option for sensitivity analysis when changing-in-step
- EOS AGA-8 added for natural gas systems
- Interfacing and performance
- Maximus engine release in KBC Acuity for deployment of cloud-based production digital twins
- Re-organized Ribbon bar is now the default view
- Improvements to the GIS map functionality
- New workflow for adding gas lift injection points into a tubing
- Ability to utilize SLB's OLGA-S (2P, 3P & HD) when it's purchased directly from SLB. Users need to request an AOL 3-J1 OLGA-S type license from SLB.
- Update to Multiflash 7.5
- Close model option added to File menu
- Short length unit added for pipe ID, etc.
- User can specify a range and step size, when adding sensitivity values
- MP profile button on results changed to Flow Map
List of known issues in Maximus 7.6
Object | Reported issue | Issue # | Work around |
---|---|---|---|
General | Oil-water LGS surface tension is inconsistent with Multiflash results | BZ-21877 | Switch model setting to Sutton+MCSA |
General | Event configurator crashes when Del is pressed several times | BZ-21874 | Avoid pressing Del more than twice in a row. |
Completion | Closing a model while running a Plot VFP calculation causes a crash | BZ-21867 | Cancel the calculation or wait until calculation is finished before closing the model |
Tuning tool | Closing a model while tuning is still running causes a crash | BZ-21859 | Stop calculation or wait until calculation is finished before closing the model |